导航菜单
网站标志
文章正文
新加坡SAC-SINGLAS资质测试认证 TüV SüD PSB资质测试认证
作者:admin    发布于:2022-02-15 14:10:40    文字:【】【】【

南京睿督公司专业提供SAC-SINGLAS新加坡认可委员会认可的实验室所出具的测试报告及证书,TüV SüD PSB资质检测报告及证书。Lab is accredited under ISO/ IEC 17025 for its quality services and certification awarded by Singapore Accreditation Council (SAC-SINGLAS). SAC新加坡实验室认可计划(SAC-SINGLAS) 。咨询电话:025-86583475

新加坡SAC-SINGLAS资质测试认证主要项目如下:

1) Fire Alarm Panel BS EN 54 Pt 2 & 4 CP10

2) Fire Pump AS 2941 UL 448 FMRC 1311 or FMRC 1319

3) Fire-rated Partition (12)
3.1) Compartment wall BS 476 Pt 4/11 or EN 13501-1  BS 476 Pt 22, EN 1364-1 AS 1530 Pt 4 ASTM E119 ISO 834 NFPA 251
3.2) Protected shaft enclosing lift (1) BS 476 Pt 4/11 EN 13501-1 BS 476 Pt 20 AS 1530 Pt 4 ASTM E119 ISO 834 NFPA 251 BS 5234 Pt 2 BS EN 520 (gypsum plaster board) ISO 1896 (calcium silicate or cement board) Cyclic loading and dynamic test as specified under clause 3.3 of Building Code of Australia C 1.8  
3.3) Protected shaft enclosing staircase or services BS 476 Pt 4/11 EN 13501-1  BS 476 Pt 22 AS 1530 Pt 4 ASTM E119 ISO 834 NFPA 251  BS 5234 Pt 2 BS EN 520 (gypsum plaster board) ISO 1896 (calcium silicate or cement board)  

4) Fire-rated Floor (1) BS 476 Pt 4/11 EN 13501-1 BS 476 Pt 21 AS 1530 Pt 4 ISO 834 For timber products, see section on cross/laminated timber

5) Fire-rated Ceiling (12)
5.1) Compartmentation BS 476 Pt 4/11 EN 13501-1  BS 476 Pt 22 EN 1364-2 AS 1530 Pt 4 ASTM E119 ISO 834 NFPA 251 For timber products, see section on cross/laminated timber

5.2) Protection to steel beams that support RC floor (1) BS 476 Pt 4/11 EN 13501-1 BS 476 Pt 23 AS 1530 Pt 4 ISO 834  

5.3) Protection to timber/ steel flooring (1) BS 476 Pt 4/11 EN 13501-1 BS 476 Pt 21 AS 1530 Pt 4 ISO 834  

6) Fire-rated Enclosure/ spraying material (12)
6.1) Protection to steel structure (1) (2) BS 476 Pt 4/11 EN 13501-1 BS 476 Pt 21 AS 1530 Pt 4 ISO 834 BS 5234 Pt 2 BS EN 520 (gypsum plaster board) ISO 1896 (calcium silicate or cement board)

6.2) Protection to firefighting system ie sprinkler, rising mains, hydrant etc (3) BS 476 Pt 4/11 EN 13501-1 FSB/PSB/001 (insulation criteria on exposed side - shall not rise more than 75oC above the initial temperature) AS 1530 Pt 4

6.3) Protection to building services ie cables, sanitary pipes, chilled water pipes etc BS 476 Pt 4/11 EN 13501-1 BS 476 Pt 20 AS 1530 Pt 4 ASTM E119 ISO 834 NFPA 251

7) Smoke Curtain (4) (12) EN 13501-1 EN 12101-1
8) Fire-rated duct system, eg. Ventilation, Smoke-extraction and/or Kitchen Exhaust Ducting System (5) (12) BS 476 Pt 4/11 EN 13501-1 BS 476 Pt 24 AS 1530 Pt 4 ASTM E119 ISO 834 NFPA 251 EN 1366-1 EN 1366-8 EN 1366-9

9) Fire Extinguishing System for Kitchen Hood UL 300

10) Fire Stopping Material (including Fire Rated Collar) BS 476 Pt 20 EN 1364-1 AS 1530 Pt 4 ASTM E119 ISO 834 NFPA 251 EN 1366 Pt3 EN 1366 Pt4 ASTM E814 ASTM 2307 - (For Curtain Wall Application)

11) Fire-rated Glass Block/ Partition/Panel (6) BS 476 Pt 22 EN 1364-1 AS 1530 Pt 4 ASTM E119 ISO 834 NFPA 251 BS 6206 AS2208 EN 12600

12) Exit sign (powered electrically) SS 263 Pt 2 SS 508 Pt 1 & 2 (Specification for Graphical Symbols - Safety Colours and Safety Signs) SS 563 Pt 1 & 2

13 ) Emergency lighting (self-contained) SS 263 Pt 2 SS 563 Pt 1 & 2

14) Battery System (for exit signs and emergency lighting) SS 563 Pt 1 & 2  

15) Self-luminous Sign (powered by radioactive material) BS 5499 Pt 2 SS 508 Pt 1 & 2 (Specification for Graphical Symbols - Safety Colours and Safety Signs) SS 563 Pt 1 & 2 

16) Fire Hosereel EN 671 Pt 1  SS 575 (Code of Practice for Fire Hydrant, Rising Mains and Hosereel Systems)  

17) Fire Fighting Hose BS 6391  

18) Auditorium Seats (7) BS 5852 Clause 12 (ignition source 0,1 & 5 )
 
19) Fire Damper For Fire Test: SS 333 Clause 6.3 AS 1530-4 (when tested to AS 1530, the damper shall be tested with the damper at open position at the start of fire test and to be able to close completely during the first 90 sec of the test) ISO 834 (when tested to AS 1530, the damper shall be tested with the damper at open position at the start of fire test and be able to completely close during the first 90 sec of the test) For air-leakage test: SS 333 Clause 6.4 ISO 5176 and ISO 7244 AS 1682-1 Clause 5.3 For closing reliability test: SS 333 Clause 6.5 UL 555 Clause 11.2 For spring closing force test: SS 333 Clause 6.6 UL 555 Clause 13
20) Fire-rated Door (13) SS 332 Clause 4 or EN 1634-1 BS 6206 or AS 2208 (applicable for glass door) EN 12600 (applicable for glass door)
21) Bin/Linen Chute Door BS 476 Pt 22 1A or 1B Labels issued by TüV SüD PSB 

22) Fire-rated Lift-landing/ Dumb Waiter Door BS 476 Pt 22 EN 81-58 (for lift-landing door) BS 6206 or AS 2208 EN 12600 (applicable for glass door)

23) Fire Shutter/Fire Curtain SS 489 Clause 3.5 & 4 or EN 1634-1 (the fire shutter/fire curtain shall close at between 10 sec and 30 sec)

24) Fire-rated Hopper / Hatch door BS 476 Pt 22 or EN 1634-1 or AS 1530 Pt 4

25) Portable Fire Extinguisher SS EN 3-7 SS EN 3-8 SS EN 3-9

26) Fire-rated Cables SS 299 Pt 1 or BS 6387 and BS 7846 (Clauses 16.2 and 16.3) 1A Mark printed on cables

27) Intumescent Coating System (for protection to steel structure) (8) BS 476 Pt 21 (for fire-resistance test) AS 1530 Pt 4 (for fire-resistance test) ISO 834 (for fire-resistance test) EN 13381-1 (for fire-resistance test) BS 8202 Pt 2 (for weathering tests) EN 16623 (for fire-resistance test & weathering tests)

28) Landing Valve BS 5041 Pt 1  

29) Breeching Inlet BS 5041 Pt 3  

30) Raised Floor Panel (9)(10) BS 476 Pt 4/11 or EN 13501-1 (applicable to the core material of composite construction)  

31) Material for Wall/Ceiling Construction (9) BS 476 Pt 4/11/7/6 & 7 EN 13501-1

32) Thermal Insulation Material (9) BS 476 Pt 4/11/7/6 & 7 EN 13501-1

33) Finishing material for wall/ ceiling (9) BS 476 Pt 4/Pt 7/Pt 6 & 7 EN 13501-1

34) Roof Covering Material (9)(14) BS 476 Pt 4/Pt 7/Pt 6 & 7 EN 13501-1 ASTM E108

35) Composite Panel ( Cladding to External Wall ) BS 476 Pt 4/Pt 6 & 7/EN 13501-1 (applicable to the core material of composite construction) NFPA 285

36) UPVC Window Frame Material (11) ASTM D635

37) Door Closer(13) / other hardware SS 332 Clause 5 or EN 179 or EN 1125 or EN 1154 or EN 1155 or EN 1158 or EN 1303 or EN 1527 or EN 1906 or EN 1935 or EN 12051 or EN 12209

38) Household Shelter Door FSSD's requirements

39) Storey Shelter Door FSSD's requirements

40) Cross / Glued Laminated Timber EN 1363 EN 1364 EN 1365

41) Materials for use in Photovoltaic (PV) Modules IEC 61730-2  Cl 10.8 or UL 790

42) Materials for Flooring EN 13501-1  

BS 476-4 https://www.fire-test.cn/newsinfo/836630.html
BS 476-6 https://www.fire-test.cn/newsinfo/836495.html
BS 476-7https://www.fire-test.cn/newsinfo/836481.html
BS 476-20 https://www.fire-test.cn/newsinfo/834881.html

南京睿督公司全国免费咨询电话:025-8658 3475   400-603-6575
网址:www.fire-test.com  www.fire-test.cn 
邮箱:info@fire-test.com  
...


地址:江苏省南京市建邺区江东中路118号德盈大厦1622
电话:025-8658 3475
传真:025-8658 3457
网址:http://www.bs6853.com/
邮箱:info@fire-test.com

脚注信息
版权所有 Copyright(C)2012-2015  南京睿督科技有限公司 版权所有  苏公网安备 32010502010099号    备案号:苏ICP备10201999号-9
图片